研究者業績

鯉渕 晴美

コイブチ ハルミ  (Harumi Koibuchi)

基本情報

所属
自治医科大学 医学部 臨床検査医学講座 准教授
学位
博士(医学)(2012年8月 自治医科大学)

研究者番号
20382848
J-GLOBAL ID
201401079156993569
researchmap会員ID
B000237602

外部リンク

学歴

 1

論文

 94
  • Kei Konno, Harumi Koibuchi, Sayaka Yamamoto, Yamato Tada, Toru Kameda, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 50(1) 115-115 2023年1月  
  • Harumi Koibuchi, Mai Ishikawa, Sayaka Yamamoto, Kei Konno, Hirofumi Okada, Yusuke Amano, Toshiyuki Yamada, Nobuyuki Taniguchi
    Journal of ultrasound 2022年12月27日  
    This report presents a case of malignant melanoma in a 40-year-old male who underwent resection of the tumor in his right ankle. Eleven months after the resection, a subcutaneous mass was observed on his right femur. Ultrasound examination revealed a hypoechoic tubular structure in the right thigh, with a small amount of blood flow in the lesion. Using ultrasound and fine-needle aspiration, the patient was diagnosed with metastasis and lymphovascular invasion of malignant melanoma. Treatment with an immune checkpoint inhibitor was originally scheduled, but the lesion disappeared spontaneously after the fine-needle aspiration.
  • Kei Konno, Harumi Koibuchi, Sayaka Yamamoto, Yamato Tada, Toru Kameda, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 49(3) 471-480 2022年7月  
    PURPOSE: Fine-needle aspiration cytology (FNAC) under ultrasound guidance is clinically useful, but there is a risk of spreading infection by generating droplets of contaminated fluids during the procedure. Risk assessment to better control infection remains to be established. The aim of this study was to estimate infection risks during FNAC by visualization of droplet production and deposition using a simulation model. METHODS: The simulation comprised a puncture needle, a device for holding the needle, and a fluid specimen containing fluorescent particles as a model. Simulating each step of FNAC (removal of the inner and outer cylinder and transferring the specimen onto a glass slide), the generation and deposition of droplets were visualized using a laser. RESULTS: After removal of the inner cylinder, an aerosol of droplets in the air surrounding the needle was observed. After removal of the outer cylinder, several large droplets precipitating onto the circumjacent surface were observed. From the beginning of transferring the specimen, a large amount of sizeable droplets first moving away and then precipitating was observed, followed by the production of a cluster of fine droplets drifting and spreading through the air. CONCLUSIONS: Here, the generation of droplets at each step of FNAC, precipitation of large droplets onto the circumjacent surface, and drifting and spreading through the air of fine droplets was visualized. These results emphasize the need for precautions to prevent the transmission of infectious agents during FNAC.
  • Toru Kameda, Harumi Koibuchi, Kei Konno, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 49(3) 415-423 2022年7月  
    PURPOSE: This study aimed to assess the feasibility and efficiency of self-learning with or without self-training (subjects performed scans on themselves) and telepresence instruction in focused cardiac ultrasound (FOCUS) education for medical students. METHODS: This study included 24 medical students. The participants initially completed a written pre-test and were randomized into a video lecture (participants watched a video lecture) or self-training (participants watched a video lecture and self-performed FOCUS) group. After finishing self-learning, they completed a written post-test. Then they undertook a skill pre-test and a first perception survey. Telepresence instruction was then provided. Finally, they undertook a skill post-test and a second perception survey. RESULTS: The written post-test total scores were significantly higher than the pre-test total scores (P < 0.001). In the skill pre-test, the scores for the video lecture and self-training groups were not significantly different (P = 0.542). The skill post-test total scores were significantly higher than the skill pre-test total scores (P = 0.008). Forty-two percent of the video lecture group participants agreed that the video lecture was effective preparation for the skill pre-test, while all participants in the same group agreed that the combination of the video lecture and telepresence instruction was effective preparation for the skill post-test. CONCLUSION: This study demonstrated the feasibility and efficiency of self-learning followed by telepresence instruction on FOCUS for medical students.
  • Toru Kameda, Nobuyuki Taniguchi, Kei Konno, Harumi Koibuchi, Kiyoka Omoto, Kouichi Itoh
    Journal of medical ultrasonics (2001) 49(2) 217-230 2022年4月  
    The concept of point-of-care ultrasound has been widely accepted owing to the development of portable ultrasound systems and growing body of evidence concerning its extensive utility. Thus, it is reasonable to suggest that training to use this modality be included in undergraduate medical education. Training in ultrasonography helps medical students learn basic subjects such as anatomy and physiology, improve their physical examination skills, and acquire diagnostic and procedural skills. Technological advances such as simulators, affordable handheld devices, and tele-ultrasound systems can facilitate undergraduate ultrasound education. Several reports have indicated that some medical schools have integrated ultrasound training into their undergraduate medical curricula. Jichi Medical University in Japan has been providing medical students with ultrasound education to fulfill part of its mission to provide medical care to rural areas. Vertical integration of ultrasound education into a curriculum seems reasonable to ensure skill retention and improvement. However, several issues have hampered the integration of ultrasound into medical education, including a lack of trained faculty, the need to recruit human models, requisition of ultrasound machines for training, and limited curricular space; proposed solutions include peer teaching, students as trained simulated patients, the development of more affordable handheld devices, and a flipped classroom approach with access to an e-learning platform, respectively. A curriculum should be developed through multidisciplinary and bottom-up student-initiated approaches. Formulating national and international consensuses concerning the milestones and curricula can promote the incorporation of ultrasound training into undergraduate medical education at the national level.
  • Harumi Koibuchi, Yasutomo Fujii, Yusuke Sato'o, Takashi Mochizuki, Toshiyuki Yamada, Longzhu Cui, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 48(4) 449-450 2021年10月  
  • Harumi Koibuchi, Yasutomo Fujii, Yusuke Sato'o, Takashi Mochizuki, Toshiyuki Yamada, Longzhu Cui, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 2021年8月19日  査読有り
    PURPOSE: We aimed to investigate whether low-intensity continuous and pulsed wave ultrasound (US) irradiation can inhibit the formation of Staphylococcus epidermidis biofilms, for potential application in the treatment of catheter-related bloodstream infections (CRBSI). METHODS: S. epidermidis biofilms that formed on the bottom surfaces of 6-well plates were irradiated on the bottom surface using the sound cell incubator system for different intervals of time. RESULTS: US irradiation with continuous waves for 24 h notably inhibited biofilm formation (p < 0.01), but the same US irradiation for 12 h had no remarkable effect. Further, double US irradiation with pulsed waves for 20 min inhibited biofilm formation by 33.6%, nearly two-fold more than single US irradiation, which reduced it by 17.9%. CONCLUSION: US irradiation of a lower intensity (ISATA = 6-29 mW/cm2) than used in a previous study and lower than recommended by the Food and Drug Administration shows potential for preventing CRBSI caused by bacterial biofilms.
  • Sayaka Yamamoto, Kei Konno, Harumi Koibuchi, Iekuni Oh, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 48(1) 107-108 2021年1月  査読有り
  • 原田 健右, 鯉渕 晴美, 藤井 康友, 紺野 啓, 山本 さやか, 山田 俊幸, 谷口 信行
    超音波医学 47(Suppl.) S568-S568 2020年11月  
  • 鯉渕 晴美, 藤井 康友, 紺野 啓, 山本 さやか, 谷口 信行, 山田 俊幸
    臨床病理 67(補冊) 225-225 2019年10月  
  • Harumi Koibuchi, Yasutomo Fujii, Yoshikazu Hirai, Takashi Mochizuki, Kohji Masuda, Kazuhiko Kotani, Toshiyuki Yamada, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 45(1) 25-29 2018年1月  査読有り
    PURPOSE: The purpose of this study was to clarify the effect of ultrasonic irradiation on biofilm produced by Staphylococcus epidermidis (S. epidermidis), which causes central venous catheter-related infections. MATERIALS AND METHODS: Staphylococcus epidermidis (S. epidermidis, ATCC 35984 RP 62A) was used in this study. First, biofilm was prepared from S. epidermidis on the bottom of the upper left well of a 6-well plate. Next, the biofilm was irradiated for 24 h with 1-MHz ultrasound (US) in the continuous wave mode to serve as the US irradiation group. The acoustic power irradiated below the bottom of the well was 3.8 mW. As a control (non-US irradiation group), non-irradiated biofilm on the bottom of a 6-well plate was incubated at 37 °C in an atmosphere of 5.0% CO2. After US irradiation, the bottoms of the wells were stained with 0.1% crystal violet for 60 s. To extract the crystal violet, 99.5% ethanol was added to the wells, and the extracted solutions were measured at an absorbance of 595 nm. RESULT: The absorbance of the US irradiation group was significantly less than that of the non-US irradiation group (p < 0.01). CONCLUSION: US irradiation can decrease the amount of S. epidermidis biofilm when the duration of US irradiation is sufficiently long even if the acoustic intensity is low.
  • Tomoyuki Kuwata, Hironori Takahashi, Harumi Koibuchi, Kiyotake Ichizuka, Michiya Natori, Shigeki Matsubara
    Journal of medical ultrasonics (2001) 43(4) 505-8 2016年10月  査読有り
    PURPOSE: To clarify the present status of human papillomavirus (HPV) contamination of transvaginal probes in Japan and propose a preventive method. METHODS: This study was performed at three institutes: a tertiary center, secondary hospital, and primary facility. To identify contamination rates, probes were disinfected and covered with probe covers and condoms; the cover was changed for each patient. The probes were tested for HPV, and those with HPV detected were analyzed to identify the type of HPV. Next, nurses put on new gloves before covering the probe for each patient, and the probes were similarly tested for HPV. RESULTS: A total of 120 probes were tested, and HPV was detected from a total of five probes, a contamination rate of 4.2 % (5/120). HPV was detected in all three institutes. Importantly, high-risk HPV, i.e., HPV-52, 56, and 59, was detected. After the "glove change strategy" was implemented, HPV was not detected on any of 150 probes tested at any of the three institutions. CONCLUSIONS: In Japan, the HPV contamination rate of vaginal probes in routine practice was 4.2 %. There was no HPV contamination of probes after changing the gloves for cover exchange for each patient. This strategy may prevent HPV probe contamination.
  • Masahiro Ebashi, Hirotoshi Oinuma, Yusuke Hidaka, Harumi Koibuchi, Kazuhiko Kotani, Toshiyuki Yamada
    Rinsho byori. The Japanese journal of clinical pathology 64(8) 887-890 2016年8月  査読有り
    The amount of monoclonal immunoglobulin (M protein) distinguishes multiple myeloma (M) from mono- clonal gammopathy of undetermined significance (MGUS) and indicates the effectiveness of treatment for MM. It should be calculated by serum total protein (g/dL) and M peak ratio (%) on the densitometry of se- rum electrophoresis. However, the ordinary method possibly overestimates the amount of M protein, be- cause this method utilizes the area from the baseline of the M peak (baseline method). For the more accu- rate measurement of M protein, in this study, we evaluated a capillary electrophoresis system that enables to extract the proper area of M peak by manual operation (peak method). Three serum samples with positive M protein were mixed with M protein negative serum at various ratio, and the measured values of M protein were compared with the theoretical values for both baseline and peak methods. All the results showed that the peak method gave the values close to the theoretical values compared with the baseline method. Espe- cially, the less M protein positive serum was mixed, the further the values by the baseline method parted from the theoretical one. In conclusion, the peak method using a capillary electrophoresis system should be introduced for the accurate quantification of M protein. [Original].
  • Harumi Koibuchi, Kazuhiko Kotani, Takaomi Minami, Kei Konno, Nobuyuki Taniguchi
    Minerva pediatrica 68(2) 143-7 2016年4月  査読有り
    Kawasaki Disease (KD) is a febrile disorder seen in infants and young children. One of the most serious complications of the disease is coronary aneurysm. Endothelial dysfunction is considered to underlie the etiopathology of coronary aneurysm. Flow-mediated dilation (FMD), as assessed ultrasonically, is used to observe the endothelial function. The current paper summarizes, by providing a systematic review, the clinical studies that have examined endothelial dysfunction by determining the FMD ultrasonically in patients with KD. A PubMed-based search found eight articles published until 2013. Six studies reported the FMD level to be significantly lower in the patients with KD compared to controls, while two studies reported no significant difference in the FMD level between those with and without KD. Although patients with KD appeared to have endothelial dysfunction in the current summary, most reports have been associated with limitations, such as a small size and no prospective design for vascular outcomes. Further studies are therefore needed to draw definite conclusions regarding whether patients with KD suffer from endothelial dysfunction as determined by the FMD and/or whether this determination can be useful for understanding and managing vascular complications in these patients.
  • Harumi Koibuchi, Kiyoka Omoto, Noriyoshi Fukushima, Tomonori Toyotsuji, Nobuyuki Taniguchi, Mikihiko Kawano
    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine 33(7) 1299-303 2014年7月  査読有り
    This report documents 3 pediatric papillary thyroid carcinoma cases with associated Hashimoto thyroiditis. In all 3 cases, hypoechoic nodules accompanied by multiple echogenic spots were noted on sonography of the thyroid. Hashimoto thyroiditis was suspected on the basis of positive thyroid autoantibody test results and pathologic examinations of thyroidectomy specimens, which revealed chronic thyroiditis with lymphocytic infiltration as the background of papillary thyroid carcinoma development. The potential for papillary carcinoma development warrants close follow-up, and meticulous sonographic examinations must be performed in children with Hashimoto thyroiditis.
  • 鯉渕 晴美, 津田 恭子, 紺野 啓, 小谷 和彦, 藤井 康友, 神田 美穂, 宮本 倫聡, 松永 宏明, 谷口 信行
    超音波医学 40(Suppl.) S636-S636 2013年4月  
  • Harumi Koibuchi, Kyoko Tsuda, Nobuyuki Taniguchi, Isamu Shimada, Tadashi Miyazawa, Takeo Sawada
    Journal of medical ultrasonics (2001) 40(2) 175-6 2013年4月  査読有り
    The aim of this study was to evaluate the effectiveness of "Protex" (Parker; Fairfield, NJ, USA) for disinfection of ultrasound probes. We examined bacterial contamination on ultrasound probes that were wiped with a plain paper towel, with a plain and an ethanol-soaked paper towel, or with a plain and Protex-soaked paper towel. The plain paper towel was used to remove the gel, and was contaminated by large numbers of bacteria, but the use of ethanol-soaked paper towels and that of paper towels soaked in Protex™ broad-spectrum disinfectant (Parker: Fairfield, NJ, USA) reduced those numbers markedly.
  • 神田 美穂, 紺野 啓, 津田 恭子, 宮本 倫聡, 松永 宏明, 鯉渕 晴美, 藤井 康友, 谷口 信行
    超音波医学 40(2) 223-223 2013年3月  
  • Harumi Koibuchi, Kazuhiko Kotani, Nobuyuki Taniguchi
    Medical ultrasonography 15(1) 41-4 2013年3月  査読有り
    Ultrasound probes are usually in a direct contact with the skin when used for detecting pathologic abnormalities. The probe could be a vector of bacterial transmission, but there have been few studies on this topic.We have made such studies, briefly reviewing 1)the conditions governing a possible bacterial transmission by probe, 2) the deterioration of an ultrasound probe by alcohol disinfection, 3) a suitable method for evaluating bacterial contamination of an ultrasound probe, and 4) the best procedure for decontaminating such probes. This paper ,may lead to a formal consideration of the relationship between ultrasound probes and their roles in bacterial transmission in clinical practice.
  • 宮本 倫聡, 小谷 和彦, 津田 恭子, 松永 宏明, 鯉渕 晴美, 藤井 康友, 紺野 啓, 山田 俊幸, 谷口 信行
    臨床病理 60(補冊) 180-180 2012年10月  
  • Kyoko Tsuda, Kei Konno, Harumi Koibuchi, Hiroaki Matsunaga, Yasutomo Fujii, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 39(3) 201-3 2012年7月  査読有り
  • 津田 恭子, 紺野 啓, 鯉渕 晴美, 宮本 倫聡, 神田 美穂, 松永 宏明, 藤井 康友, 谷口 信行
    超音波医学 39(Suppl.) S397-S397 2012年4月  
  • 鯉渕 晴美, 紺野 啓, 尾本 きよか, 神田 美穂, 津田 恭子, 宮本 倫聡, 松永 宏明, 藤井 康友, 谷口 信行
    超音波医学 39(Suppl.) S492-S492 2012年4月  
  • 松永 宏明, 紺野 啓, 中澤 成公, 神田 美穂, 津田 恭子, 宮本 倫聡, 鯉渕 晴美, 藤井 康友, 尾本 きよか, 谷口 信行
    超音波医学 39(2) 178-178 2012年3月  
  • 津田 恭子, 鯉渕 晴美, 紺野 啓, 松永 宏明, 宮本 倫聡, 神田 美穂, 藤井 康友, 谷口 信行
    超音波医学 39(2) 181-181 2012年3月  
  • Shunji Hayashi, Harumi Koibuchi, Nobuyuki Taniguchi, Yoshikazu Hirai
    Journal of medical ultrasonics (2001) 39(1) 11-4 2012年1月  査読有り
    PURPOSE: To determine suitable procedures for decontaminating ultrasound probes. METHODS: We investigated bacterial transmission via ultrasound probes that were not wiped, wiped with a plain paper towel, or wiped with an ethanol-soaked paper towel. RESULTS: The unwiped probes transmitted large numbers of bacteria, which were markedly reduced by wiping the probes with a plain paper towel, and almost completely eliminated by wiping with an ethanol-soaked paper towel. CONCLUSION: Improperly decontaminated ultrasound probes can transmit bacteria among patients. Ultrasound probes should be decontaminated by wiping with a paper towel after examinations to prevent bacterial transmission. Plain or ethanol-soaked paper towels should be used depending on the situation.
  • Shigeyoshi Kijima, Kiyoka Omoto, Kenichi Utano, Atsuko Sakamoto, Hiroaki Matsunaga, Harumi Koibuchi, Yasutomo Fujii, Nobuyuki Taniguchi, Kei Konno, Hideharu Sugimoto
    Journal of medical ultrasonics (2001) 39(1) 29-31 2012年1月  査読有り
    Sister Mary Joseph's nodule (SMJN), which is known as a malignant tumor metastasized to the umbilicus, is a rare condition. We report ultrasonic findings of SMJN secondary to ovarian cancer in a 66-year-old woman. The umbilical tumor was observed as a hypoechoic mass with punctate hyperechoic foci. A pathological specimen obtained by needle biopsy confirmed adenocarcinoma with psammoma bodies. A comparison of the ultrasonographic findings with the pathological findings of the resected specimen suggested that the hyperechoic foci corresponded to psammoma bodies. When hyperechoic foci are observed inside SMJN by ultrasonography, adenocarcinoma from ovarian cancer should be included in the differential diagnosis.
  • 松永 宏明, 宮本 倫聡, 小形 幸代, 鯉渕 晴美, 藤井 康友, 紺野 啓, 尾本 きよか, 谷口 信行, 西野 宏, 藤井 博文
    超音波医学 38(3) 328-329 2011年5月  
  • 紺野 啓, 藤井 康友, 鯉渕 晴美, 松永 宏明, 荻原 友美菜, 谷口 信行, 石田 秀明
    超音波医学 38(Suppl.) S326-S326 2011年4月  
  • 紺野 啓, 藤井 康友, 鯉渕 晴美, 松永 宏明, 倉井 順子, 荻原 友美菜, 谷口 信行
    超音波医学 38(Suppl.) S498-S498 2011年4月  
  • Harumi Koibuchi, Yasutomo Fujii, Kazuhiko Kotani, Kei Konno, Hiroaki Matsunaga, Michiaki Miyamoto, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 38(2) 97-100 2011年4月  査読有り
    The aim of this study was to clarify the degree of degradation of ultrasonic probes that results from their disinfection with alcohol. No defect in the ultrasound beams was found in any of the probes, but a significant decrease of the brightness was found after a certain period of use of the linear-type probe. Disinfection with alcohol may degrade ultrasound probes despite its high degree of effectiveness in preventing iatrogenic bacterial transmission.
  • 宮本 倫聡, 小谷 和彦, 松永 宏明, 鯉渕 晴美, 藤井 康友, 紺野 啓, 山田 俊幸, 石橋 俊, 谷口 信行
    臨床病理 58(補冊) 113-113 2010年7月  
  • 紺野 啓, 鯉渕 晴美, 藤井 康友, 松永 宏明, 高橋 純子, 谷口 信行, 石田 秀明
    超音波医学 37(Suppl.) S388-S388 2010年4月  
  • 鯉渕 晴美, 小谷 和彦, 藤井 康友, 紺野 啓, 松永 宏明, 宮本 倫聡, 谷口 信行
    超音波医学 37(Suppl.) S412-S412 2010年4月  
  • Michiaki Miyamoto, Kazuhiko Kotani, Hiroaki Yagyu, Harumi Koibuchi, Yasutomo Fujii, Kei Konno, Toshiyuki Yamada, Shun Ishibashi, Nobuyuki Taniguchi
    Journal of physiological anthropology 29(4) 149-52 2010年  査読有り
    We examined the relationship between the coefficient of variation in the R-R intervals (CVR-R) using electrocardiograms and the ultrasonic intima-media thickness (IMT) of the carotid artery, an atherosclerotic parameter, in type 2 diabetes mellitus (DM) patients with diabetic neuropathy (n=47, males/females: 29/18; mean age: 62 years). In this study, the CVR-R-related indexes, including CVR-R at rest (CVR-R(rest)), CVR-R with deep breaths (CVR-R(breath)) and their difference (CVR-R(breath) minus CVR-R(rest): CVR-R(dif)), were defined. Data such as body mass index, smoking habits, hemoglobin A1c, blood pressure, and serum low-density lipoprotein were collected. A significant inverse correlation was observed between max-IMT and CVR-R(dif) (beta=-0.34, p=0.042), but not CVR-R(rest) or CVR-R(breath), in multivariate analyses adjusted for all the data. Therefore, the CVR-R(dif) may serve as a clinical index for the diabetic autonomic neuropathy-atherosclerosis relation in type 2 DM patients.
  • Kazuhiko Kotani, Harumi Koibuchi, Michiaki Miyamoto, Toshiyuki Yamada, Nobuyuki Taniguchi
    Medical principles and practice : international journal of the Kuwait University, Health Science Centre 19(6) 496-8 2010年  査読有り
    OBJECTIVE: It was the aim of this study to investigate whether there is any relationship between oxidative stress, as assessed by the diacron reactive oxygen metabolite (d-ROM) test, and carotid atherosclerosis among hypercholesterolemic patients. SUBJECTS AND METHODS: A well-defined group of patients with type II hypercholesterolemia (n = 81, mean age 59 years) was studied to observe the correlation between the levels of serum d-ROMs and carotid artery intima-media thickness (IMT) using B-mode ultrasound, in relation to the traditional atherosclerotic risk factors (age, sex, smoking, body mass index, blood pressure, glucose and lipid panels). RESULTS: The mean level in low-density lipoprotein cholesterol (LDL-C) in this population was 4.45 mmol/l, d-ROMs were 323.2 Carr U, and IMT was 0.91 mm. A multiple regression analysis revealed a positive and significant correlation between IMT and d-ROMs (β = 0.27, p < 0.05), along with age and LDL-C. CONCLUSION: These results indicate that the increased oxidative stress levels using the d-ROM test, independent of aging and increased LDL-C levels, may be associated with carotid atherosclerosis even in hypercholesterolemic patients.
  • Shuumarjav Uurtuya, Kazuhiko Kotani, Harumi Koibuchi, Michiaki Miyamoto, Kazuomi Kario, Toshiyuki Yamada, Nobuyuki Taniguchi
    Clinical and experimental hypertension (New York, N.Y. : 1993) 32(8) 517-22 2010年  査読有り
    Hypertension (HT) and C-reactive protein (CRP) are risk factors of cardiovascular diseases (CVD). The current study's purpose was to investigate the relationship between serum CRP levels and daily lifestyles, including physical activity, in Japanese HT patients. Lifestyle factors, blood pressure (BP), blood cholesterol, glucose, and CRP were measured in a total of 312 HT patients (153 men/159 women, mean age: 62.6 y). Women with physical activity of ≥ 1 time/week showed significantly lower CRP levels than those without it (p < 0.05). The data suggest that regular physical activity could reduce the CRP levels in HT patients, thereby maybe preventing CVD.
  • Harumi Koibuchi, Shunji Hayashi, Kazuhiko Kotani, Yasutomo Fujii, Kei Konno, Yoshikazu Hirai, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 36(4) 187-187 2009年12月  査読有り
    PURPOSE: To determine suitable methods for evaluating bacterial contamination of ultrasound probes. METHODS: We compared probe imprinting, swab streaking, and swab suspension methods for evaluating bacterial contamination of ultrasound probes. RESULTS: Experimental and clinical investigations showed that the sensitivity for detecting bacterial contamination of ultrasound probes was higher with probe imprinting than with swab methods. Probe imprinting was very simple and required only agar plates. CONCLUSION: Probe imprinting was the most suitable method for evaluating bacterial contamination of ultrasound probes.
  • Kazuhiko Kotani, Harumi Koibuchi, Toshiyuki Yamada, Nobuyuki Taniguchi
    Clinica chimica acta; international journal of clinical chemistry 409(1-2) 67-9 2009年11月  査読有り
    BACKGROUND: Lifestyle modification improves the pathophysiology of lipid disorder, leading to the development of cardiovascular disease (CVD). While oxidized low-density lipoprotein (oxLDL) may be involved in this mechanism, various oxLDL measurements have recently been developed and therefore further detailed studies are called for in this area. Our aim was to investigate the effects of lifestyle modification on serum amyloid A-LDL (SAA-LDL), a new oxLDL, in subjects with primary lipid disorder. METHODS: A total of 141 asymptomatic subjects (women/men=100/41, mean age 57.6 years) with>or=1 lipid abnormality (circulating high levels of low-density lipoprotein cholesterol [LDL-C] and triglyceride [TG] or low levels of high-density lipoprotein cholesterol [HDL-C]), who completed a 6-month lifestyle modification program in combination with diet and exercise, were analyzed. In the pre- and post-intervention, the metabolic variables including SAA-LDL were assessed. RESULTS: During our intervention, the body mass index, blood pressure, LDL-C, TG, glucose and SAA-LDL significantly decreased, while HDL-C significantly increased. Multiple regression analysis revealed that the change levels of TG (positive) and HDL-C (inverse) were significantly and independently correlated to those of SAA-LDL. CONCLUSIONS: These results suggest that SAA-LDL may contribute to the link between lipid disorder and the development of CVD, and that the application of SAA-LDL measurements may be useful for the assessment of the risk of CVD as a biochemical marker.
  • Kenichi Utano, Kiyoka Omoto, Harumi Koibuchi, Natsuki Take, Hiroaki Matsunaga, Nobuyuki Taniguchi
    Journal of medical ultrasonics (2001) 36(3) 145-8 2009年9月  査読有り
    A 7-year-old female infant presented with an asymptomatic soft tissue mass in the right neck. The tumor was considered to be a benign one because it had a smooth margin and no change in its size was observed. Ultrasonography showed a 4.5-cm-diameter solid tumor with a smooth, well-defined border. Inside the tumor, flow signals were observed on color Doppler and there were numerous echogenic spots. Magnetic resonance imaging (MRI) examination showed findings consistent with an ectopic thymus, i.e., T1- and T2-weighted images showed thymus-like signals. The course of the case is being continuously followed.
  • 宮本 倫聡, 小谷 和彦, 野牛 宏晃, 鯉渕 晴美, 藤井 康友, 紺野 啓, 山田 俊幸, 石橋 俊, 谷口 信行
    臨床病理 57(補冊) 211-211 2009年7月  
  • Shuumarjav Uurtuya, Kazuhiko Kotani, Harumi Koibuchi, Nobuyuki Taniguchi, Toshiyuki Yamada
    Journal of atherosclerosis and thrombosis 16(3) 299-300 2009年6月  査読有り
  • 鯉渕 晴美, 林 俊治, 藤井 康友, 紺野 啓, 尾本 きよか, 谷口 信行
    超音波医学 36(Suppl.) S296-S296 2009年4月  
  • 紺野 啓, 鯉渕 晴美, 藤井 康友, 谷口 信行, 石田 秀明
    超音波医学 36(Suppl.) S401-S401 2009年4月  
  • Harurni Koibuchi, Yasutomo Fujii, Nobuyuki Taniguchi
    JOURNAL OF CLINICAL ULTRASOUND 36(6) 369-370 2008年7月  査読有り
    Glomus tumors are benign tumors that originate in a neuromyoarterial glomus body and most commonly occur in the subungual regions. We present an unusual case of a glomus tumor in a subcutaneous vein of the dorsum of the wrist in a 65-year-old man and describe its gray-scale and power Doppler sonographic appearance, with a brief discussion of the clinical and histologic findings. (C) 2008 Wiley Periodicals, Inc.
  • 竹 夏樹, 黒崎 仁寛, 鯉渕 晴美, 藤井 康友, 高野 隆一, 紺野 啓, 尾本 きよか, 谷口 信行
    超音波医学 35(2) 235-235 2008年3月  
  • 歌野 健一, 中田 和佳, 小林 茂, 黒崎 仁寛, 鯉渕 晴美, 尾本 きよか, 谷口 信行
    超音波医学 35(2) 235-236 2008年3月  
  • Yasutomo Fujii, Nobuyuki Taniguchi, Harumi Koibuchi, Yoshikazu Yasuda, Hideo Nagai
    Journal of clinical ultrasound : JCU 36(2) 59-62 2008年2月  査読有り
    PURPOSE: To evaluate the use of sonography in the assessment of compressibility of the affected bowel in the differential diagnosis of gastrointestinal (GI) lymphoma. METHODS: Thirty-two cases of advanced gastric cancer, 28 cases of advanced colon cancer, 7 cases of gastric lymphoma, and 6 cases of colon lymphoma were included in the study. To assess the compressibility of the affected bowel, a transducer was used to exert external compression. Deformation of the tumor and its lumen by compression was considered to indicate positive compressibility. RESULTS: Compressibility was absent in advanced gastric and colon cancer but was present in 11/13 (85%) cases of GI lymphoma. In the diagnosis of GI lymphoma, compressibility showed 85% (11/13) sensitivity, 97% (58/60) specificity, and 95% (69/73) overall accuracy. CONCLUSION: Compressibility of the affected bowel is a useful clue in the diagnosis of GI lymphoma.
  • 竹 夏樹, 黒崎 仁寛, 鯉渕 晴美, 藤井 康友, 高野 隆一, 紺野 啓, 尾本 きよか, 谷口 信行
    日本超音波医学会関東甲信越地方会学術集会抄録集 19回 82-82 2007年11月  
  • 歌野 健一, 中田 和佳, 小林 茂, 黒崎 仁寛, 鯉渕 晴美, 尾本 きよか, 谷口 信行
    日本超音波医学会関東甲信越地方会学術集会抄録集 19回 82-82 2007年11月  

MISC

 67

共同研究・競争的資金等の研究課題

 6